February 26, 2026
With IP68-rated* water and dust protection, the fan is designed to keep operating reliably in harsh environments such as washdown, grease, and mist. The fan stops before being submersing in water and starts working after coming out the water. The key point is not only ingress protection, it is maintaining predictable cooling performance when water or oily fluids are part of daily operation.
Example idea of 1 of the fans
What means “industrial-grade” in practice (more than just IP rating)
When we talk about splash-proof and oil-proof fans, we also look at the fundamentals that drive reliability and qualification:
Materials
Frame and impeller in UL 94V-0 plastic.
Relevant for flammability requirements in industrial systems.
Motor protection
Locked-rotor burnout protection and reverse polarity protection.
Designed to reduce field failures from wiring mistakes and stalled operation.
Electrical robustness
Dielectric strength: 500 VAC, 1 minute between leads and frame
Insulation resistance: 10 MΩ minimum at 500 VDC (between lead wire conductors and frame)
Acoustics definition | Sound Pressure Level
The SPL is specified A-weighted at 1 meter from the inlet.
Temperature handling
Storage -20 to +60 / +70°C, non-condensing.
Useful for logistics and outdoor deployments.
Wiring and control
Lead set for power, sensor, and control lines (Red, Black, Sensor, Yellow, Control, Brown).
Mechanical integration
Mass 240 g ~ 930g, which matters for vibration design, mounting, and structural resonance.
MAIN APPLICATIONS
• Industrial kitchens and exhaust systems, washdown and grease exposure
• Factory automation, coolant mist, cleaning cycles, harsh dust and splash
• Outdoor systems like EV chargers, weather exposure and reliability expectations
• Agricultural machinery, mud, water, and cleaning with pressure and fluids
• Storage batteries and energy storage systems, continuous thermal management in compact enclosures
• PV inverters, outdoor installations with long-life reliability requirements
• Digital signage, exposure to weather, dust, and intermittent maintenance cleaning
• Plant factories, high humidity environments and frequent cleaning cycles
There are several variants available, and the right choice depends on your system requirements.
Across the portfolio you will find differences in:
There are several variants available, and the right choice depends on your system requirements. Share your requirements and we will support you with selection and design-in guidance so the fan matches your use case.
* The degree of protection of our products are rated as per IEC 60529 (International Electrotechnical Commission). The protection ratings of our fans only apply to electrical components (motor coils and elec-
tronic components) and do not cover mechanical components (blades, frames, bearings, etc.).
Fans
9WPA0424H6002
9WL0624P4H001
9WPA0624M4002
9WL0824H4002
9WPA0824H4002
9WL0924H1D001
9WG1224E102-E
9WPA1224J4001
Amplifier
GADSA03AA22
AC Servo
GAM2A6040F0XRK0
If you tell us your environment, fluid type, duty cycle, and cleaning process, we can help you select the right fan variant and define the control approach.